Error Code
Description
Troubleshooting
No AC connection (302)
No utility grid connected or utility grid power failure
Check AC isolator or circuit breaker. If both are ON and issue persists, submit a maintenance service request
AC V outrange (300)
Utility grid voltage is out of permissible range
Switch off DC switch. Check AC wiring, especially neutral/ground. Restart inverter. If problem persists, contact Growatt.
AC F outrange (304)
Utility grid frequency is out of range
Switch off DC switch. Check AC wiring and grid frequency. Restart inverter. If problem persists, contact Growatt.
Over temperature (408)
Temperature out of range
Ensure inverter is not covered. Restart inverter. If issue persists and temp < 60°C, contact Growatt
PV isolation low (203)
Insulation problem
Check panel/inverter grounding. Check DC breaker for moisture. Measure impedance. If still faulty, contact Growatt.
Output high DCI (402)
Independent operation detected
Restart inverter. If error remains, contact Growatt.
Residual I high (201)
Leakage current too high
Restart inverter. If error remains, contact Growatt.
PV voltage high (202)
DC input voltage exceeds max tolerance
Disconnect DC switch immediately. Check PV voltage with multimeter. If <550V and issue persists, contact Growatt.
Auto test failed (407)
Auto test didn’t pass
Restart inverter. If problem persists, contact Growatt.
100
Voltage fault
Submit a maintenance request to installer.
101
Communication fault
Shut down inverter fully by turning off DC switch. Restart. If error persists, submit a maintenance request.
102
Master and slave processor data mismatch
Same as Error 101. Shut down and restart inverter. Submit request if error persists.
116
EEPROM fault
If error occurs all day, restart inverter. If error continues, control board may need replacement. Contact Growatt.
117 / 405
Relay fault
Restart inverter. If problem remains, submit a service request.
118
Init model fault
Submit a maintenance request to installer.
119 / 420
GCFI device damage / GFCI fault
Restart inverter 2–3 times. If error persists, contact Growatt. May require power board replacement.
120
HCT fault (Current sensor issue)
Restart inverter. If issue remains, contact Growatt.
121
Master processor not receiving data from slave
Same as Error 101 & 102.
122
Bus voltage fault
Submit a maintenance request to installer.
PE abnormal (303)
Voltage between Neutral and PE above 30V
Check wiring and Neutral-PE voltage. Restart inverter. If issue remains, contact manufacturer.
Warning 203
PV1 or PV2 Circuit short
Check PV polarity. Restart inverter. If warning persists, contact Growatt to replace power board.
Warning 204
Dryconnect function abnormal
After shutdown, check Dryconnect wiring. Contact manufacturer if warning remains.
Warning 205
PV1 or PV2 boost broken
Restart inverter. If issue persists, contact Growatt to replace power board.
Warning 207
USB over-current
Unplug USB/monitor. Reconnect after shutdown. If issue remains, contact manufacturer.
Warning 401
Inverter-Meter communication abnormal
Ensure meter is ON and properly connected to inverter.
Warning 404 / Error 414
EEPROM abnormal
Restart inverter. If issue persists, replace M3 board or contact Growatt.
Warning 405
Firmware version mismatch
Update firmware to correct version.
Error 404
Bus sample fault
Restart inverter. If issue remains, contact Growatt.
Error 409
Bus over-voltage
Restart inverter. If issue remains, contact Growatt.
Error 411
DSP-M3 communication issue
Restart inverter. If persists, update DSP & M3 firmware or replace DSP/M3 board.
Error 417
DSP and redundant M3 sampling data mismatch
Restart inverter. If issue persists